Device Roles in a System

Introduction

There are numerous device classes used in a Tesira system:

Server Class Devices

This includes SERVER, SERVER IO and TesiraFORTÉ hardware devices.

Tesira Server class devices have the following common features:

The ability to:

Component object use

Tesira Server class devices accept the placing of all DSP and Logic Component Objects (So long as the Hardware IO supports the function)

Amplifier Class Devices (rack-mount)

Note

The Lab.Gruppen amplifier and Plenum-Mount amplifiers operate as an Audio Expander class device and requires a Server Class device to act as a Proxy.

Tesira rack-mount amplifier devices have the following common features:

The ability to:

Component object use

Tesira Rack-Mount Amplifiers accept the placing of the following blocks TesiraXEL amps do not accept placing of logic blocks:

Input / Output Logic Controls
   

  More information on these devices may be found here: Tesira Amplifiers - Rack Mount 

TesiraLUX Class Devices

This includes the IDH-1 and OH-1 hardware devices.

TesiraLUX devices have the following common features:

The ability to:

Component object use

TesiraLUX accept the placing of the following blocks :

Input/ Outputs and Routers Logic Controls

 

Audio Expander Class Devices

This includes the EX-MOD, EX-AEC, EX-IN, EX-OUT, EX-IO, EX-UBT / EX-USB, Parlé Microphones, Tesira Amplifiers - Plenum Mount, NPX* and Lab.gruppen Amplifier hardware devices.

Tesira audio expander class devices have the following common features:

The ability to:

Audio expander class devices require a Server class device to be discovered and managed from Tesira software. This includes the following maintenance tasks:

*Firmware updates and network management are performed by the software communicating directly with the NPX..

NOTE: DSP blocks can not be allocated to an TCM-1/TCM-X, TCM-1A/TCM-XA, TTM-X, AMP-450P/AMP-450BP, EX-UBT / EX-USB or an NPX in the software.

Logic Expander Class Devices

This includes the EX-LOGIC hardware device.

Logic expander class devices require a Server class device to be discovered and managed from Tesira software. This includes the following maintenance tasks:

Control Class Devices

This includes the TEC-1HD-1, TEC-X 1000 and TEC-X 2000 hardware devices.

Control class devices require a Server class device to be discovered and managed from Tesira software. This includes the following maintenance tasks:

TesiraCONNECT

TC-5

TC-5 is an AVB capable PoE+ device designed for use in Tesira conference systems to connect Tesira devices.

The TC-5 is unique in the Tesira family of devices:

See Device Maintenance for specific information on what maintenance tasks may be performed on the TesiraCONNECT.

TC-5D

TC-5D is a Dante and AVB capable PoE+ device designed for use in conference systems to connect Biamp AVB and Dante devices.