Output

If an analog output is required, the Output processing block should be selected. When this component is selected from the Object Toolbar, an Output Initialization dialog is produced.

Initialization Dialog

Name Description Range
Channel Count Provides a dropdown where the number of channels can be selected. If Custom is selected from the drop-down list the number of channels can be specified. 1-24
Equipment Type specifies what type of hardware the compiler should allocate the block to. Review the Equipment Type section for more details.  

DSP Block Representation

Control Dialog

 

Name Description Range
Device IO Indicates which physical hardware input is associated with that software channel. For SERVER and SERVER-IO devices is formatted as x.y - where x indicates which card slot and y indicates which channel on the card.  
Mute turns the input signal on/off. On or Off
Level adjusts the relative input volume. -100 to +12
Invert adjusts the polarity of the input signal. 0° or 180°
Full Scale (dBu) The amount of analog gain for specifying differing output levels (mic or line). -31 (Mic level), 0dBu to +24dBu in 6dB steps