If an analog output is required, the Output processing block should be selected. When this component is selected from the Object Toolbar, an Output Initialization dialog is produced.
Name | Description | Range |
Channel Count | Provides a dropdown where the number of channels can be selected. If Custom is selected from the drop-down list the number of channels can be specified. | 1-24 |
Equipment Type | specifies what type of hardware the compiler should allocate the block to. Review the Equipment Type section for more details. |
Name | Description | Range |
Device IO | Indicates which physical hardware input is associated with that software channel. For SERVER and SERVER-IO devices is formatted as x.y - where x indicates which card slot and y indicates which channel on the card. | |
Mute | turns the input signal on/off. | On or Off |
Level | adjusts the relative input volume. | -100 to +12 |
Invert | adjusts the polarity of the input signal. | 0° or 180° |
Full Scale (dBu) | The amount of analog gain for specifying differing output levels (mic or line). | -31 (Mic level), 0dBu to +24dBu in 6dB steps |