Please refer to the TTP Overview section for more details on the controlling Tesira devices using the TTP protocol.
Each element of the command instruction is delimited by one or more spaces. The commands are case sensitive and upper and lower case characters are used.
The TTP string to adjust a DSP object attribute is structured in the following order:
Instance_Tag Command Attribute [Index] [Value] LF
Instance Tag | Command | Attribute Code | Index | Value |
LogicDelay1 | set | offDelayMs | 1 | 1000 |
Example |
LogicDelay1 set offDelayMs 1 1000 +OK |
Reason Code
|
Attribute Code |
Command |
Indexes |
Value Range |
Bypass | bypass | get / set toggle | channel | false, true |
Off Delay | offDelayMs | get / set increment decrement | channel | 0 - 60000 ms |
On Delay | onDelayMs | get / set increment decrement | channel | 0 - 60000 ms |