Voltera D & DM Amplifier Blocks

Status Attributes

Please refer to the TTP Overview section for more details on the controlling Tesira devices using the TTP protocol.

Each element of the command instruction is delimited by one or more spaces. The commands are case sensitive and upper and lower case characters are used.

The TTP string to adjust a DSP object attribute is structured in the following order:

Instance_Tag Command Attribute [Index] [Value] LF

 

Instance Tag

Attribute Code

Command

Index

Value

 VDAmp1

 level

 set

 1

 -3.0

 

Reason Code
Attribute Code
Command
Indexes
Value Range
Amplifier Fault Indicator ampFault get / subscribe / unsubscribe   false, true
Amplifier Warning Indicator ampWarning get / subscribe / unsubscribe   false, true
Input Label  inputLabel get / set channel  
User Input dB level get / set / subscribe / unsubscribe channel  minLevel - maxLevel dB
User Input Percent levelPercent get / set / subscribe / unsubscribe channel minLevel - maxLevel percent
User Input Mute mute get / set / subscribe / unsubscribe channel false, true
Mute All muteAll get / set / subscribe / unsubscribe   false, true
Amplifier Output Clipping outputClip get / subscribe / unsubscribe   false, true
Loudspeaker Output dB outputLevel get / subscribe / unsubscribe channel minLevel - maxLevel dB
All Loudspeaker Output Levels outputLevels get / subscribe / unsubscribe    
Output Label outputLabel get / set  channel  
Power Profile Info powerProfile get   LIVE_PERFORMANCE  LIVE_GREEN

 

Services

Service Service Code Parameters
Sleep Device sleep  
Wake Devie wake