Please refer to the TTP Overview section for more details on the controlling Tesira devices using the TTP protocol.
Each element of the command instruction is delimited by one or more spaces. The commands are case sensitive and upper and lower case characters are used.
The TTP string to adjust a DSP object attribute is structured in the following order:
Instance_Tag Command Attribute [Index] [Value] LF
Reason Code
|
Attribute Code |
Command |
Indexes |
Value Range |
Connection Status | connected | get subscribe unsubscribe | false, true | |
Host Master Mute Status | hostMasterMute | get subscribe unsubscribe | false, true | |
Host Master Volume Control Level | hostMasterVol | get subscribe unsubscribe | -100.0 - 12.0 dB | |
Level | level | get/set increment decrement | channel | minLevel - maxLevel dB |
All Levels | levels | get | ||
Max Level | maxLevel | get/set increment decrement | channel | minLevel - 12.0 dB |
Min Level | minLevel | get/set increment decrement | channel | -100.0 - maxLevel dB |
Mute | mute | get/set/toggle | channel | false, true |
All Mute States | mutes | get | ||
Channel Count | numChannels | get | 1 - 8 | |
Peak Occurring | peak | get subscribe unsubscribe | channel | false, true |
All Peaks | peaks | get subscribe unsubscribe | ||
Streaming Status | streaming | get subscribe unsubscribe | false, true |