Tesira Rack Mount Amplifier Block

Service Codes

Each element of the Service Code instruction is delimited by a single space. The commands are case sensitive and upper and lower case characters are used. The TTP string is structured in the following order:

Instance_Tag Service [Index] [Value] LF

Instance Tag

Service

TAmp1

select

 

Description

Service

Index

Value

Identify amplifier

select

 

 

 

Status Attributes

Please refer to the TTP Overview section for more details on the controlling Tesira devices using the TTP protocol.

Each element of the command instruction is delimited by one or more spaces. The commands are case sensitive and upper and lower case characters are used.

The TTP string to adjust a DSP object attribute is structured in the following order:

Instance_Tag Command Attribute [Index] [Value] LF

 

Reason Code
Attribute Code
Command
Indexes
Value Range
Amplifier Fault Indicator ampFault get subscribe unsubscribe   false, true
Amplified Output Mute All Channels ampMuteAll get set toggle subscribe unsubscribe   false, true
Amplifier Power ampPower get set toggle subscribe unsubscribe   false, true
Amplifier Standby Timeout ampStandbyTimeout get set   STANDBY_TIMEOUT_DISABLED, STANDBY_TIMEOUT_15, STANDBY_TIMEOUT_30, STANDBY_TIMEOUT_45, STANDBY_TIMEOUT_60
Amplifier Thermal Fault Indicator ampThermalFault get subscribe unsubscribe   THERMAL_NONE, THERMAL_WARNING, THERMAL_FAULT
Amplifier Warning Indicator ampWarning get subscribe unsubscribe   false, true
Amplified Output AVB Stream Present Indicator AVBstreamPresent get subscribe unsubscribe channel false, true
Amplified Output Expected Load Impedance expectedImpedance get set channel EXPECT_8_OHMS, EXPECT_4_OHMS
Amplified Output Failover Active Indicator failoverActive get subscribe unsubscribe channel false, true
Failover Input Gain failoverGain get set increment decrement channel 0 - 66 dB in 6 dB increments
Amplified Output Failover Input Channel failoverInputChannel get set increment decrement channel Failover input channel or 0 for none
Failover Input Invert failoverInvert get set toggle channel false, true
Failover Input Level failoverLevel get set increment decrement subscribe unsubscribe channel failoverMinLevel - failoverMaxLevel dB
Failover Input Level Max failoverMaxLevel get set increment decrement channel failoverMinLevel - 12.0 dB
Failover Input Level Min failoverMinLevel get set increment decrement channel -100.0 - failoverMaxLevel dB
Failover Input Mute failoverMute get set toggle subscribe unsubscribe channel false, true
Failover Input Peak Indicator failoverPeak get subscribe unsubscribe channel false, true
Failover Input Phantom Power failoverPhantomPower get set toggle channel false, true
Failover Input Signal Present Indicator failoverSignalPresent get subscribe unsubscribe channel false, true
Failover Input Signal Present Threshold failoverSignalPresentThreshold get set increment decrement channel -64.0 - 30.0 dB
Amplified Output Failover Test failoverTest get set toggle subscribe unsubscribe channel false, true
Front Panel Lock frontPanelLock get set toggle subscribe unsubscribe   false, true
Amplified Output Sensitivity gain get set increment decrement channel 0 - 24 dB in 6 dB increments
Amplified Output High Impedance Indicator highImpedance get subscribe unsubscribe channel HIGH_IMPEDANCE_NONE, HIGH_IMPEDANCE_OPEN
Amplified Output Input Meter inputLevel get subscribe unsubscribe channel -100.0 - 36.0 dB
Amplified Output Invert invert get set toggle channel false, true
Amplified Output Level level get set increment decrement subscribe unsubscribe channel minLevel - maxLevel dB
Amplified Output Limiter Attenuation limiterAttenuation get subscribe unsubscribe channel LIMITER_ATTENUATION_NONE, LIMITER_ATTENUATION_LIMITING, LIMITER_ATTENUATION_CLIPPING
Amplified Output Limiter Enable limiterEnable get set toggle channel false, true
Amplified Output Low Impedance Indicator lowImpedance get subscribe unsubscribe channel LOW_IMPEDANCE_NONE, LOW_IMPEDANCE_LOWZ, LOW_IMPEDANCE_SHORT
Amplified Output Level Max maxLevel get set increment decrement channel minLevel - 0.0 dB
Amplified Output Level Min minLevel get set increment decrement channel -100.0 - maxLevel dB
Amplified Output Mute mute get set toggle subscribe unsubscribe channel false, true
Amplified Output Current outputCurrentLevel get subscribe unsubscribe channel any value for Arms
Amplified Output Voltage outputVoltageLevel get subscribe unsubscribe channel any value for Vrms
Selected Time selectedTime get subscribe unsubscribe   0 - 2147483647 s
Amplified Output Standby Threshold standbyThreshold get set increment decrement channel -100.0 - 0.0 dB
Amplified Output Thermal Fault Indicator thermalFault get subscribe unsubscribe channel false, true
Amplified Output Thermal Warning Indicator thermalWarning get subscribe unsubscribe channel false, true