Please refer to the TTP Overview section for more details on the controlling Tesira devices using the TTP protocol.
Each element of the command instruction is delimited by one or more spaces. The commands are case sensitive and upper and lower case characters are used.
The TTP string to adjust a DSP object attribute is structured in the following order:
Instance_Tag Command Attribute [Index] [Value] LF
Instance Tag |
XAmp1 |
Reason Code
|
Attribute Code |
Command |
Indexes |
Value Range |
Amplified Output Allowed Power | allowedPowerWatts | get | channel | 0-1200 |
Amplifier Fault Indicator | ampFault | get subscribe unsubscribe | false, true | |
Amplifier Fault String | ampFaultString | get subscribe unsubscribe | String indicating amplifier default | |
Amplifier Mute All Channels | ampMuteAll | get set toggle subscribe unsubscribe | false, true | |
Amplifier Warning Indicator | ampWarning | get subscribe unsubscribe | false, true | |
Amplified Output Auto Mute Threshold | automuteThreshold | get set increment decrement | channel | -100.0 - 0.0 |
Amplified Output Auto Mute Timeout | automuteTimeout | get set | channel | AUTOMUTE_TIMEOUT_DISABLED, AUTOMUTE_TIMEOUT_15, AUTOMUTE_TIMEOUT_30, AUTOMUTE_TIMEOUT_45, AUTOMUTE_TIMEOUT_60 |
Amplified Output Expected Load | expectedLoad | get | channel | EXPECT_4_OHMS, EXPECT_8_OHMS, EXPECT_70_V, EXPECT_100_V |
Front Panel Lock | frontPanelLock | get set toggle subscribe unsubscribe | false, true | |
Amplified Output Input Clipping | inputClip | get set subscribe unsubscribe | channel | false, true |
Amplified Output Input Meter | inputLevel | get subscribe unsubscribe | channel | -100.0 - 36.0 dBu |
Amplified Output Invert | invert | get set toggle | channel | false, true |
Amplified Output High Pass Filter Enable | highPassFilterEnable | get set toggle | false, true | |
Amplified Output Level | level | get set increment decrement subscribe unsubscribe | channel | minLevel - maxLevel dBu |
Amplified Output Limiter Attenuation | limiterAttenuation | get subscribe unsubscribe | channel | LIMITER_ATTENUATION_NONE LIMITER_ATTENUATION_LIMITING LIMITER_ATTENUATION_CLIPPING |
Amplified Output Impedance | impedance | get subscribe unsubscribe | channel | IMPEDANCE_NONE, IMPEDANCE_LOWZ, IMPEDANCE_SHORT IMPEDANCE_OPEN |
Amplified Output Level Max | maxLevel | get set increment decrement | channel | minLevel - 0.0 dBu |
Amplified Output Level Min | minLevel | get set increment decrement | channel | -100.0 - maxLevel dBu |
Amplified Output Mute | mute | get set toggle subscribe unsubscribe | channel | false, true |
Amplified Output Clipping | outputClip | get subscribe unsubscribe | channel | false, true |
Amplified Output Meter | outputLevel | get subscribe unsubscribe | channel | -100.0 - 36.0 |
Amplified Output Protection | protect | get subscribe unsubscribe | channel | false, true |
Amplified Output Fault Reporting Enable | reportingEnable | get set toggle | channel | false, true |
Channel Automute Threshold | automuteThreshold | get set increment decrement | channel | -100.0 - 0.0 dB |
Amplified Output Thermal Protection |
thermal | get subscribe unsubscribe | channel | THERMAL_NONE THERMAL_WARNING THERMAL_FAULT |