TI Receive Block

Please refer to the TTP Overview section for more details on the controlling Tesira devices using the TTP protocol.

Each element of the command instruction is delimited by one or more spaces. The commands are case sensitive and upper and lower case characters are used.

The TTP string to adjust a DSP object attribute is structured in the following order:

Instance_Tag Command Attribute [Index] [Value] LF


Instance Tag Command Attribute Code
TIReceive1 get level

Example
TIReceive get level +OK "value":0.000000

Reason Code
Attribute Code
Command
Value Range
Line Echo Cancel lec get /set toggle false, true
Input Level level get / set increment decrement minLevel - maxLevel dB
Max Input Level maxLevel get / set increment decrement minLevel - 12.0 dB
Min Input Level minLevel get / set increment decrement -100.0 - maxLevel dB
Mute mute get / set toggle subscribe unsubscribe false, true
Channel Count numChannels get Always 1
Ring Tone Level ringLevel get / set increment decrement -100.0 - 0.0 dB