Please refer to the TTP Overview section for more details on the controlling Tesira devices using the TTP protocol.
Each element of the command instruction is delimited by one or more spaces. The commands are case sensitive and upper and lower case characters are used.
The TTP string to adjust a DSP object attribute is structured in the following order:
Instance_Tag Command Attribute [Index] [Value] LF
Reason Code
|
Attribute Code
|
Command
|
Indexes
|
Value Range
|
Channel Name (Dante 'RX Channel Label') | channelName | get / set | channel | Case-insensitive, up to 31 characters except '=' '.' '@' '\' '<' '>' |
Device Name (Dante 'Hostname of TX Device') | deviceName | get subscribe unsubscribe | channel | |
All Device Names (Dante 'Hostnames of all TX Devices') | deviceNames | get subscribe unsubscribe | ||
Invert | invert | get/set/toggle | channel | false, true |
Level | level | get / set increment decrement subscribe unsubscribe | channel | minLevel - maxLevel dB |
All Levels | levels | get subscribe unsubscribe | ||
Max Level | maxLevel | get / set increment decrement | channel | minLevel - 12.0 dB |
Microphone Model | micModel | get | MXA910 MXA310 ANYTYPE | |
Min Level | minLevel | get / set increment decrement | channel | -100.0 - maxLevel dB |
Mute | mute | get / set toggle subscribe unsubscribe | channel | false, true |
All Mute States | mutes | get subscribe unsubscribe | ||
Channel Count | numChannels | get | 1 - 64 | |
Peak Occurring | peak | get subscribe unsubscribe | channel | false, true |
All Peaks | peaks | get subscribe unsubscribe |