Labgruppen Amp

Service Codes

Each element of the Service Code instruction is delimited by a single space. The commands are case sensitive and upper and lower case characters are used. The TTP string is structured in the following order:

Instance_Tag Service [Index] [Value] LF

Instance Tag

Service

LGAmp1

select

 

Description

Service

Index

Value

Identify Amplifier

select

 

 

 

Status Attributes

Please refer to the TTP Overview section for more details on the controlling Tesira devices using the TTP protocol.

Each element of the command instruction is delimited by one or more spaces. The commands are case sensitive and upper and lower case characters are used.

The TTP string to adjust a DSP object attribute is structured in the following order:

Instance_Tag Command Attribute [Index] [Value] LF

  
Reason Code
Attribute Code
Command
Indexes
Value Range
Amplifier Name ampName get    
Amplifier Power ampPower get / set toggle   false, true
Amplified Output Amp Status ampStatus get subscribe unsubscribe channel STATUS_OK, STATUS_WARNING, STATUS_ERROR, STATUS_UNKNOWN
Amplified Output Amp Status Reason ampStatusReason get channel Reason code for any indicator
Amplified Output Auto Power Down Threshold apdThreshold get / set increment decrement channel -100.0 - 0.0 dB
Auto Power Down Timeout apdTimeoutMins get / set increment decrement   0 - 60 min
Amplified Output Channel Name channelName get channel  
Failover Input Gain failoverGain get / set increment decrement channel 0 - 66 dB in 6 dB increments
All Failover Input Indicators failoverIndicators get subscribe unsubscribe    
Amplified Output Failover Input Channel failoverInputChannel get channel Failover input channel or 0 for none
Failover Input Invert failoverInvert get / set toggle channel false, true
Failover Input Level failoverLevel get / set increment decrement channel failoverMinLevel - failoverMaxLevel dB
Failover Input Level Max failoverMaxLevel get / set increment decrement channel failoverMinLevel - 12.0 dB
Failover Input Level Min failoverMinLevel get / set increment decrement channel -100.0 - failoverMaxLevel dB
Failover Input Mute failoverMute get / set toggle channel false, true
Failover Input Peak Indicator failoverPeak get subscribe unsubscribe channel false, true
Failover Input Phantom Power failoverPhantomPower get / set toggle channel false, true
Failover Input Signal Present Indicator failoverSignalPresent get subscribe unsubscribe channel false, true
Failover Input Signal Present Threshold failoverSignalPresentThreshold get / set increment decrement channel -64.0 - 30.0 dB
Amplified Output Failover Test failoverTest get / set toggle channel false, true
Amplified Output Failover Test Active Indicator failoverTestActive get subscribe unsubscribe channel false, true
Frame Status frameStatus get subscribe unsubscribe   STATUS_OK, STATUS_WARNING, STATUS_ERROR, STATUS_UNKNOWN
Frame Status Reason frameStatusReason get   Reason code for any indicator
All Frame Indicators indicators get subscribe unsubscribe    
Amplified Output Invert invert get / set toggle channel false, true
Amplified Output Level level get / set increment decrement channel minLevel - maxLevel dB
Amplified Output Load Status loadStatus get subscribe unsubscribe channel STATUS_OK, STATUS_WARNING, STATUS_ERROR, STATUS_UNKNOWN
Amplified Output Load Status Reason loadStatusReason get channel Reason code for any indicator
Amplified Output Level Max maxLevel get / set increment decrement channel minLevel - 0.0 dB
Amplified Output Level Min minLevel get / set increment decrement channel -100.0 - maxLevel dB
Amplified Output Mute mute get /set toggle channel false, true
Selected Time selectedTime get subscribe unsubscribe   0 - 2147483647 s
Amplified Output Signal Status signalStatus get subscribe unsubscribe channel STATUS_OK, STATUS_WARNING, STATUS_ERROR, STATUS_UNKNOWN
Amplified Output Signal Status Reason signalStatusReason get channel Reason code for any indicator
 

Status Indicator Reason Codes

Indicator reasons provide the user with more detail of indicators by way of text strings. It is possible for this list to change but has no functional effect on the amplifier product.   

Reason Code

Text in GUI

Comment

1

PSU SAFEMODE PSU is in safe mode
2 SENS FLT:DSP There is no activity in voltage and current sense on any channel when power is ON
3 AUDIO FAULT   Deactivated Audio OK/ or missing audio clocks.  
4 NEED SERVICE:1 The PSU did not get the PFC state OK signal after turning on the PFC in three attempts OR PFCStateOk has gone low during normal operation (HW error)
5 NEED SERVICE:2 The PSU did not get the DC state OK signal after turning on the DC/DC in three attempts OR DCStateOk has gone low during normal operation (HW error)
6 NEED SERVICE:3   The PFC output voltage did not reach the level where the DC/DC should be turned on within the required time
7 NEED SERVICE:4   Communication with DICO was lost  
  8   NEED SERVICE:5   PSU A/D interrupts are not running  
9 NEED SERVICE:6 NTC fault is detected on a PSU temp sensor
10 NEED SERVICE:7 Board Id not recognized  
11 NEED SERVICE:8 Supply voltages to the DSP are failing – This is Analog Ok lost!
12 TEMP FLT:PSU Temp warning indicator
13 TEMP FLT:DSP Temp warning indicator for P20 slot (Host/DICO4)
14 MAINS >400 VPK Mains peak voltage is too high for continued operation
15 MAINS >270 V Mains RMS voltage is too high for continued operation.
16 MAINS <65 V (MAINS <65V) Mains RMS voltage is too low for continued operation

17

PSU FAULT Mains power supply failing. Supply voltages to the DSP are failing

18

CHECK MAINS The PFC overvoltage protection (HW) tripped. Retry in 10 seconds

19

UVL ACTIVE Output power limited by mains input under voltage

20

PSU RAIL PROT An internal voltage went below minimum operating level due to an extreme power demand (40 Hz square wave at 0 dBFS) – This is HW Power Good Lost!

21

TEMP FAULT   Temp warning indicator  

22

NO LOAD Load monitor detected no load.

23

SHORT CIRCUIT Short Circuit Fault

24

  SERVICE CH.   Amp channel needs service fault

25

  WRONG LOAD     Load monitor correct speaker is connected.  

26

CAL ACTIVE Average current limiter is active

27

CURRENT CLIP   Current Clip One flash red with defined after glow (400ms)  

28

VHF FAULT Very High Frequency Fault. (15kHz continuously @+2dBu)

29

PAL ACTIVE (PAL) Active limitation of mains input due to risk of breaking mains fuse. This flag is valid only for PLM10000 and PLM14000. For PLM20000 see PSU status block below.

30

VOLTAGE CLIP Voltage Clip One flash red with defined after glow (400ms)

31

BEL ACTIVE Output power limited by fuse model

32

PAL ACT. WARN Output power limited by mains input current

33

PTL ACTIVE Output power limited by PSU overheat

34

ATL ACTIVE    Output power limited by amp overheat  

35

MAINS GLITCH A glitch < 8 cycles on the mains voltage was detected. PSU was not turned off.

36

TEMP WARN: PSU   Temp warning indicator

37

  TEMP WARN     Temp warning indicator

38

UNDER SPKR CNT Load monitor detected fewer speakers than expected

39

OVER SPKR CNT Load monitor detected more speakers than expected

40

SPKR SHORT Load monitor speaker magnet temperature warning. Change applies from Tesira v2.3 on

41

SPKR DAMAGED Load monitor voice coil temperature warning

42

UNCERTAIN LOAD Load monitor is uncertain if correct load is connected or not

43

SELFTEST ERR  

44

SELFTEST WARN  

45

UPGRADE PSU