Please refer to the TTP Overview section for more details on the controlling Tesira devices using the TTP protocol.
Each element of the command instruction is delimited by one or more spaces. The commands are case sensitive and upper and lower case characters are used.
The TTP string to adjust a DSP object attribute is structured in the following order:
Instance_Tag Command Attribute [Index] [Value] LF
Reason Code
|
Attribute Code
|
Command
|
Indexes
|
Value Range
|
Channel Name (in Dante terms, 'TX Channel Label') | channelName | get / set | channel | Case-insensitive, up to 31 characters except '=' '.' '@' '\' '<' '>' |
Invert | invert | get/set/toggle | channel | false, true |
Level | level | get/set increment decrement subscribe unsubscribe | channel | minLevel - maxLevel dB |
All Levels | levels | get subscribe unsubscribe | ||
Max Level | maxLevel | get/set increment decrement | channel | minLevel - 0.0 dB |
Min Level | minLevel | get/set increment decrement | channel | -100.0 - maxLevel dB |
Mute | mute | get/set toggle subscribe unsubscribe | channel | false, true |
All Mute States | mutes | get subscribe unsubscribe | ||
Channel Count | numChannels | get | 1 - 2 |