AVB Output Block

Please refer to the TTP Overview section for more details on the controlling Tesira devices using the TTP protocol.

Each element of the command instruction is delimited by one or more spaces. The commands are case sensitive and upper and lower case characters are used.

The TTP string to adjust a DSP object attribute is structured in the following order:

Instance_Tag Command Attribute [Index] [Value] LF


Reason Code
Attribute Code
Command
Indexes
Value Range
AVB Data Format format get   LINEAR_PCM, FLOAT_32, GENERIC_32
Invert invert get / set toggle channel false, true
Level level get / set increment decrement subscribe unsubscribe channel minLevel - maxLevel dB
Max Level maxLevel get / set increment decrement channel minLevel - 0.0 dB
Min Level minLevel get / set increment decrement channel -100.0 - maxLevel dB
Mute mute get / set toggle channel false, true
Channel Count numChannels get   1 - 60
Stream Connection Status streamActive get subscribe unsubscribe   false, true
AVB Stream Name streamName get    

Enable Redundant Stream

useCableRedundancy

get

 

false, true