The TTP string to adjust a DSP object attribute is structured in the following order:

Instance_Tag Command Attribute [Index] [Value] LF


Instance Tag Command Attribute Code
Anc1 get numChannels

Example
Anc1 get numChannels +OK "value":2

Reason Code
Attribute Code
Command
Indexes
Value Range
Ambient Threshold ambThreshold get / set increment decrement channel -100.0 - 0.0 dBu
Bypass bypass get / set toggle channel false, true
Compensation Max maxGain get / set increment decrement channel 0.0 - 25.0 dB
All Meter States meters get subscribe unsubscribe channel  
Channel Count numChannels get   1 - 16
Compensation Ratio ratio get / set increment decrement channel 0.25 - 1.0
Response Time Down responseTimeDown get / set increment decrement channel 500.0 - 300000.0 ms
Response Time Up responseTimeUp get / set increment decrement channel 500.0 - 300000.0 ms