AEC Input Block

The following attribute tables relate to any AEC Input processing Blocks.

 

Please refer to the TTP Overview section for more details on the controlling Tesira devices using the TTP protocol.

Each element of the command instruction is delimited by one or more spaces. The commands are case sensitive and upper and lower case characters are used.

The TTP string to adjust a DSP object attribute is structured in the following order:

Instance_Tag Command Attribute [Index] [Value] LF


Instance Tag Command Attribute Code Value
Aec1 get aecEnable 1
  Confirm number of channels and set Input gain on Channel 1
Example
AecInput1 get numChannels +OK "value":2   AecInput1 get gain 1 +OK "value":0.000000   AecInput1 set gain 1 48 +OK

Reason Code
Attribute Code
Command
Indexes
Value Range
Gain gain get / set increment decrement channel 0 - 66 dB in 6 dB increments
Channel Count numChannels get   1 - 24
Peak Occurring peak get subscribe unsubscribe channel false, true
All Peaks peaks get subscribe unsubscribe    
Phantom Power On phantomPower get / set toggle subscribe unsubscribe channel false, true
All Phantom Power States phantomPowers get subscribe unsubscribe