The following attribute tables relate to any AEC Input processing Blocks.
Please refer to the TTP Overview section for more details on the controlling Tesira devices using the TTP protocol.
Each element of the command instruction is delimited by one or more spaces. The commands are case sensitive and upper and lower case characters are used.
The TTP string to adjust a DSP object attribute is structured in the following order:
Instance_Tag Command Attribute [Index] [Value] LF
Instance Tag | Command | Attribute Code | Value |
Aec1 | get | aecEnable | 1 |
Example |
AecInput1 get numChannels +OK "value":2 AecInput1 get gain 1 +OK "value":0.000000 AecInput1 set gain 1 48 +OK |
Reason Code
|
Attribute Code |
Command |
Indexes |
Value Range |
Gain | gain | get / set increment decrement | channel | 0 - 66 dB in 6 dB increments |
Channel Count | numChannels | get | 1 - 24 | |
Peak Occurring | peak | get subscribe unsubscribe | channel | false, true |
All Peaks | peaks | get subscribe unsubscribe | ||
Phantom Power On | phantomPower | get / set toggle subscribe unsubscribe | channel | false, true |
All Phantom Power States | phantomPowers | get subscribe unsubscribe |