Please refer to the TTP Overview section for more details on the controlling Tesira devices using the TTP protocol.
Each element of the command instruction is delimited by one or more spaces. The commands are case sensitive and upper and lower case characters are used.
The TTP string to adjust a DSP object attribute is structured in the following order:
Instance_Tag Command Attribute [Index] [Value] LF
Instance Tag | Command | Attribute Code | Value |
ToneGenerator1 | set | sweepEnable | true |
Reason Code
|
Attribute Code |
Command |
Value Range |
Frequency | frequency | get / set increment decrement | 20.0 - 20000.0 Hz |
Frequency Increment | frequencyInterval | get / set | OCTAVE_1, OCTAVE_2_3, OCTAVE_1_3, OCTAVE_1_6, OCTAVE_1_12, OCTAVE_1_24, OCTAVE_1_48, OCTAVE_1_96 |
Level | level | get / set increment decrement | minLevel - maxLevel dBu |
Max Level | maxLevel | get / set increment decrement | minLevel - 36.0 dBu |
Min Level | minLevel | get / set increment decrement | -100.0 - maxLevel dBu |
Mute | mute | get / set toggle | false, true |
Sweep Enabled | sweepEnable | get / set toggle | false, true |
Sweep Start Frequency | sweepFrequencyStart | get / set increment decrement | 20.0 - 20000.0 Hz |
Sweep Stop Frequency | sweepFrequencyStop | get / set increment decrement | 20.0 - 20000.0 Hz |
Sweep Increment Time | timeInterval | get / set increment decrement | 10 - 60000 ms |