Ducker Block

Please refer to the TTP Overview section for more details on the controlling Tesira devices using the TTP protocol.

Each element of the command instruction is delimited by one or more spaces. The commands are case sensitive and upper and lower case characters are used.

The TTP string to adjust a DSP object attribute is structured in the following order:

Instance_Tag Command Attribute [Index] [Value] LF

 

Instance Tag Command Attribute Code
Ducker1 get attackTime

 

 

Example
Ducker1 get attackTime

 

 

Attribute Attribute Code Commands Value Range
Attack Time attackTime get / set increment decrement 0.1 - 2000.0 ms
Bypass bypass get / set toggle false, true
Ducking Level duckingLevel get / set increment decrement -100.0 - 0.0 dB
Input Level inputLevel get / set increment decrement -100.0 - 12.0 dB
Input Mute inputMute get / set toggle false, true
Logic In Enabled logicInEnable get / set toggle false, true
Logic In Inverted logicInInvert get / set toggle false, true
Logic Out Enabled logicOutEnable get / set toggle false, true
Logic Out Inverted logicOutInvert get / set toggle false, true
Max Input Level maxInputLevel get / set increment decrement minInputLevel - 12.0 dB
Min Input Level minInputLevel get / set increment decrement -100.0 - maxInputLevel dB
Mix Sense Enabled mixSense get/set toggle false, true
Release Time releaseTime get / set increment decrement 0.1 - 40000.0 ms
Sense Level senseLevel get / set increment decrement -100.0 - 12.0 dB
Sense Mute senseMute get / set toggle false, true
Threshold threshold get / set increment decrement -60.0 - 24.0 dBu