Compressor Block

Please refer to the TTP Overview section for more details on the controlling Tesira devices using the TTP protocol.

Each element of the command instruction is delimited by one or more spaces. The commands are case sensitive and upper and lower case characters are used.

The TTP string to adjust a DSP object attribute is structured in the following order:

Instance_Tag Command Attribute [Index] [Value] LF

 


Reason Code
Attribute Code
Command
Indexes
Value Range
GR Levels allGainReduction get subscribe unsubscribe    
Attack Time attackTime get / set increment decrement   1.0 - 2000.0 ms
Bypass bypass get / set toggle   false, true
Gain Reduction gainReduction get subscribe unsubscribe channel 1 - 32
Makeup Gain makeupGain get / set increment decrement   0.0 - 12.0 dB
Channel Count numChannels get   1 - 32
Release Time releaseTime get / set increment decrement   5.0 - 10000.0 ms