Please refer to the TTP Overview section for more details on the controlling Tesira devices using the TTP protocol.
Each element of the command instruction is delimited by one or more spaces. The commands are case sensitive and upper and lower case characters are used.
The TTP string to adjust a DSP object attribute is structured in the following order:
Instance_Tag Command Attribute [Index] [Value] LF
Reason Code
|
Attribute Code |
Command |
Indexes |
Value Range |
GR Levels | allGainReduction | get subscribe unsubscribe | ||
Attack Time | attackTime | get / set increment decrement | 1.0 - 2000.0 ms | |
Bypass | bypass | get / set toggle | false, true | |
Gain Reduction | gainReduction | get subscribe unsubscribe | channel | 1 - 32 |
Makeup Gain | makeupGain | get / set increment decrement | 0.0 - 12.0 dB | |
Channel Count | numChannels | get | 1 - 32 | |
Release Time | releaseTime | get / set increment decrement | 5.0 - 10000.0 ms |