FORTÉ TI

TesiraFORTÉ TI

The TesiraFORTÉ TI Component objects adds Input and output blocks associated with a FORTÉ TI hardware device.

Initialization Dialog

Name Description
AEC Ref Mode Determines how the AEC Reference block will be displayed and operate
  • Single Channel - one common reference point for all channels.
  • Single Channel with pass-through - one common reference point for all channels plus an output node for the AEC Ref signal to be passed through. Typically placed in-line with the room output so as the room level increases/decreases, the signal going to the reference increases/decreases proportionately. If this output node is left unterminated, the AEC inputs and subsequent processing objects will be seen as an incomplete signal path and ignored by the Compiler.
  • Per channel - a separate reference point for each channel of AEC. Typically used for mix-minus referencing.
Preconfigure for Beamtracking Mics Optimizes AEC settings for use with Beamtracking microphones.
Use TI Enables telephone ports and allows for specific region selection.
Use USB Opens the USB Channel Initialization dialog.

 

DSP Block Representation

 

The TesiraFORTÉ TI will add the following default component objects:

Optional:

NOTE: Beamtracking defaults may be reset from the context menu of the AEC block by right-clicking and selecting "Reset to Beamtracking Defaults."

Default Configuration

Each TesiraFORTÉ device comes pre-configured from the factory with a default system design (see design layout below). If you wish to load your own custom designed configuration you will need to reset/initialize the unit(s) first. The default system files are installed with the Tesira software package and may be reloaded to the unit at a later stage if cleared.