Peak or RMS Meter Block

Please refer to the TTP Overview section for more details on the controlling Tesira devices using the TTP protocol.

Each element of the command instruction is delimited by one or more spaces. The commands are case sensitive and upper and lower case characters are used.

The TTP string to adjust a DSP object attribute is structured in the following order:

Instance_Tag Command Attribute [Index] [Value] LF


Instance Tag Command Attribute Code Index Index Value
AudioMeter2 subscribe level 3 myspecialmeter 5000

Example - To subscribe and unsubscribe to a meter.
AudioMeter2 subscribe level 3 myspecialmeter 5000   ! "publishToken":"myspecialmeter" "value":-100.000000 +OK   ! "publishToken":"myspecialmeter" "value":-70.000000 ! "publishToken":"myspecialmeter" "value":-40.000000   AudioMeter2 unsubscribe level 3 myspecialmeter +OK

Reason Code
Attribute Code
Command
Indexes
Value Range
Hold Enabled holdEnabled get / set toggle channel false, true
Hold Time holdTime get / set increment decrement channel 0.0 - 1000.0 ms
Hold Indefinitely indefiniteHold get / set toggle channel false, true
Label label get / set channel  
Level level get subscribe unsubscribe channel -100.0 - 36.0 dB
All Levels levels get subscribe unsubscribe    
Channel Count numChannels get   1 - 32