Parlé/AMP-450P/AMP-450BP

Status Attributes

Refer to the TTP Overview section for more details on the controlling Tesira devices using the TTP protocol.

Each element of the command instruction is delimited by one or more spaces. The commands are case sensitive; upper and lower case characters are used.

The TTP string to adjust a DSP object attribute is structured in the following order:

Instance_Tag Command Attribute [Index] [Value] LF

 

Reason Code
Attribute Code
Command
Indexes
Value Range

Amplifier Fault Indicator

ampFault get    subscribe unsubscribe   false, true

Amplified Output Mute All Channels

ampMuteAll get/set/toggle/subscribe/unsubscribe   false, true
Amplified Thermal Fault Indicator ampThermalFault get    subscribe unsubscribe   THERMAL_NONE THERMAL_WARNING THERMAL_FAULT
Amplifier Warning Indicator ampWarning get    subscribe unsubscribe   false, true

Amplified Output Clip

clip get   subscribe unsubscribe channel CLIP_NONE CLIP_CLIPPING
Amplified Output Invert invert get set toggle    channel false, true
Amplified Output Level level get set increment decrement    subscribe unsubscribe channel minLevel - maxLevel dB
Amplified Output Levels levels get/subscribe/unsubscribe    
Amplified Output Load Impedance loadImpedance get    set channel

LOAD_8_OHMS

LOAD_4_OHMS

Amplified Output Max Level maxLevel get set increment decrement    channel minLevel - 0.0 dB
Amplified Output Min Level minLevel get set increment decrement    channel    -100.0 - maxLevel dB  
Amplified Output Mute mute get set toggle    subscribe unsubscribe channel false, true
Amplified Output Mutes mutes get   subscribe unsubscribe   Array of booleans
Amplifier Channel Count numChannels   get   1-4
Amplified Output Protection protection get/subscribe/unsubscribe channel PROTECTION_NONE PROTECTION_LIMITING PROTECTION_MUTED