Attero Tech Output Block

Please refer to the TTP Overview section for more details on the controlling Tesira devices using the TTP protocol.

Each element of the command instruction is delimited by one or more spaces. The commands are case sensitive and upper and lower case characters are used.

The TTP string to adjust a DSP object attribute is structured in the following order:

Instance_Tag Command Attribute [Index] [Value] LF


Reason Code
Attribute Code
Command
Indexes
Value Range
Channel Name (in Dante terms, 'TX Channel Label') channelName get channel Case-insensitive, up to 31 characters except '=' '.' '@' '\' '<' '>'
Invert invert get/set/toggle channel false, true
Level level get/set increment decrement subscribe unsubscribe channel minLevel - maxLevel dB
All Levels levels get subscribe unsubscribe    
Max Level maxLevel get/set increment decrement channel minLevel - 0.0 dB
Min Level minLevel get/set increment decrement channel -100.0 - maxLevel dB
Mute mute get/set toggle subscribe unsubscribe channel false, true
All Mute States mutes get subscribe unsubscribe    
Channel Count numChannels get   1 - 2