All Pass Filter Block

Please refer to the TTP Overview section for more details on the controlling Tesira devices using the TTP protocol.

Each element of the command instruction is delimited by one or more spaces. The commands are case sensitive and upper and lower case characters are used.

The TTP string to adjust a DSP object attribute is structured in the following order:

Instance_Tag Command Attribute [Index] [Value] LF


Instance Tag Command Attribute Code Index
AllPassFilter1 get frequency 1

Example
AllPassFilter1 get frequency  

Reason Code
Attribute Code
Command
Indexes
Value Range
Bandwidth bandwidth get / set increment decrement band 0.01 - 4.0 oct
Bypass bypass get / set toggle band false, true
Bypass All bypassAll get / set toggle   false, true
Center Frequency frequency get / set increment decrement band 20.0 - 20000.0 Hz
Band Enabled isUsed get / set toggle band false, true
Band Count numBands get   1 - 16